Supporting Information ACS catalysis-1005
incubation, a SPME fiber (30 µm polydimethylsiloxane, Supelco, Sigma-Aldrich Group, Bellefonte, PA) was manually inserted into the headspace vial and incubated at 25 C for 12.5 min. GC-MS analysis was conducted on a Varian CP-3800 instrument
Residual Monomers in Polymers by Multiple Headspace Extraction using the Aijiren Headspace
Pure monomers were purchased from Sigma-Aldrich. These were analyzed by full evaporation in 10-mL headspace vials as external standards. Typically, 0.1 µL of the pure monomer was injected directly into a sealed headspace vial. A regression analysis of the
Agricultural acceleration of soil carbonate weathering -
The sample was shaken gently and left to equilibrate at room temperature for at least 24 hr. After preparation, CO 2 was directly extracted cryogenically from the vial headspace into a customized high vacuum extraction line using a 1:1 ethanol–dry ice mix as a 2.
Headspace Technique - an overview | ScienceDirect
Raw ground pork was put in the headspace vial, water was added and using a manual procedure the sample was heated for 30 min in a water bath. After cooling to room temperature, the vial was placed in the autosampler adapted to perform HS-SPME.
Aijiren GC-FID & Headspace Autosampler |
GC Headspace Sampler (HT2000H) - Brand NEW 42 Position (20ml) headspace vial rack Headspace Starter Kit: 20ml vials, caps, septa (10pcs) Preventative Maintenance Kit - Link General Purpose Remote Cable HPIB Communication G2070 Data system
A Solid-phase Micro-extraction GC-MS/MS Method for Rapid
Add to the headspace vial 9980 µL of water or fill up to the mark on the volumetric flask 1. Weigh 100 mg of homogenized sample to the headspace vial or volumetric flask 3. Add to the sample 2.5 g of NaCl 4. T ig h t ly ca p ev w n osur with Butyl/PTFE septa 5.
Closures | VWR
VWR supports you in your autosampler vial selection process through on-site consultations with our Chromatography Specialists, and providing samples when needed. Avantor Seradigm VWR provides the cell culture community with access to the most reliable supply of exceptional quality Fetal Bovine Serum: VWR Life Science Seradigm.
10 mL Headspace Vials - Headspace Vials by volume |
17 列 · Sigma-Aldrich Online Catalog Product List: 10 mL Headspace Vials Product # Description
Lab Equipment and Lab Supplies | Fisher Scientific -
2 mL Vial (3) 2 to 2.5 mL Standard Opening Vial (1) 20 mm Crimp Seal, 22 mm Cap (1) 20 mm Crimp Seal, 22 mm Screw Cap (1) 20 mm Headspace Seals - MicroLiter (1) 20, 40 or 60 mL Vial (7) 22 mL Vial (7) 25 and 40 mL Screw Cap Septum Vial, 240 mL (8
OpenLAB CDS ChemStation Edition C.01.06 Tips and Tricks for GC
Headspace Sampler •Pause gives the options •Abort: aborts the run; sequence stop •Retry: Retries the current vial •Skip: Skips the current vials and goes to the next line of the sequence The action can be preselected Pause, Skip, or Stop. May 2014 26
New Headspace Grade Solvents - Fisher Sci
transferred to a 20 mL headspace GC (HSGC) vial. 2. Ten tablets were dissolved in a mixture of water and DMSO (50:50). The mixture was centrifuged and the supernatant transferred to a 20 mL HSGC vial. Headspace GC-FID run conditions
Headspace vial, clear glass, beveled top, flat bottom |
Headspace vial, clear glass, beveled top, flat bottom volume 20 mL, O.D. × H × I.D. 23 mm × 75 mm × 12.5 mm, pkg of 100 ea; find Sigma-Aldrich-27199 MSDS, related peer-reviewed papers, technical documents, similar products & more at Sigma-Aldrich.
Experimental Considerations in Headspace Gas Chromatography
Incubation of the headspace vial is an important con-sideration in headspace-GC method development. If the tylamine, and allylamine were purchased from Sigma
Sensitivity Flexibility Simplicity - Teledyne Tekmar
Headspace Vial Sampler To be successful in today’s laboratory, you have to do more with less – less time, less bench space and less budget for new instrumentation. Teledyne Tekmar can help you do just that with the HT3 Automated Static and Dynamic
(PDF) An engineered pathway for the biosynthesis of
Ten microlitres of the headspace of 2 ml gas-tight GC vials were injected in 10:1 split mode (1.5 ml min 1 He flow, injector at 250 ° C, 35 ° C for 2 min then to 50 ° C with 5 ° Cm i n 1 ).